Wake-up signal for Scania Communicator, short circuit

Error identification

Wake-up signal for Scania Communicator is short-circuited to ground.

 

Cause

Fault in harness-to-component connectors or cable harness for the wake-up signal for Scania Communicator.

Internal fault in ALM control unit E7.

Notes

Symptom

The alarm system cannot initiate Scania Communicator.

 

Action

Disconnect the harness-to-component connector to ALM control unit pin A5.

Measure for short circuits throughout the cable harness.

If there are a number of harness-to-component connectors between the wake-up signal and the ALM control unit, disconnect them and measure in order to isolate the fault.