Description
Doosan DL06/DL08 Stage V Engine Diagnostic Software 2024.10
Doosan DL06/DL08 Stage V Engine Features:
Size:158MB
Date:2024.10
Version:v02.20
Language:English,Korean,Chinese
OS Requires:Win7,Win8,Win10 and Win11
Compatible Interface:Doosan UVIM Diagnostic Tool
Price only for one PC installation and activation.
Doosan DL06/DL08 Stage V Engine Functions:
Fault Codes
Data Monitoring
Data Analysis
Snapshot Viewer
Engine Test
Input/Output Test
DPF regen by scan tool
Part replacement
Reprogramming
ECU Information
Summary
Doosan DL06 DL08 Diagnostic Software 2024.10 Video Show:
Doosan DL06 DL08 Diagnostic Software 2024.10 Update Log:
sw ver : 02.20
date : 2024-10-04
Corrected EngPrt_TrqLimMech_f RMBA(Read Memory By Address)
. The variable address for reading EngPrt_TrqLimMech_f has been corrected on ECU SW V450.
Updated Freeze Frame Signal ID Information
. DL0608 StageV Freezeframe_강진구책임_20240314.xlsx
Applying Security Access Logic
Added uvim S Communication Protocol. uvim S USB, uvim S WIFI, uvim S BT
Updated EnvSet for DTCs related to environment pressure fault
. P2227, P1227, P2229, P2228, P006D : xSet13 ➔ xSet12
(Approved)DL0608_Stage5_진단장치_통합파일_20240930.xlsx
Changed the displaying format for CoETS_stCurrLimActive
. Modified to change the format from DEC to BIN and to save it in Excel file and to monitor in the data monitoring menu.
Changed the notation format for DFES_numDFC_[x]
. Changed from displaying the existing HEX values to monitoring in Pcode format for ECU SW V450 only.
. Display format – Change to the following format so that errors can be identified during the conversion of HEX values.”
(Approved)DL0608_Stage5_진단장치_통합파일_20240930.xlsx
[HEX]:[Fault Name]:[Pcode] [Description]
(e.g.) 98:DFC_ComDlcTSC1VE:U005A CAN data length error of TSC1VE(VCU) :ENG Ver.
98:DFC_ComDlcTSC1VE:U005A TSC1VE CAN 신호 데이터 길이 이상(VCU) :KOR Ver.
98:DFC_ComDlcTSC1VE:U005A TSC1VE(VCU)的 CAN 数据长度异常 : CHN Ver.
Updated Trouble Shooting Guide v1.70
. Trouble Shooting Guide_DL06_08_Stage V_CN4_CHN_v1.70.pdf
. Trouble Shooting Guide_DL06_08_Stage V_CN4_ENG_v1.70.pdf
. Trouble Shooting Guide_DL06_08_Stage V_CN4_KOR_v1.70.pdf
Added Variables related to RMBA 18EA
. (Approved)DL0608_Stage5_진단장치_통합파일_20240930.xlsx
==============================================
sw ver: 02.15_R2
date: 2024-02-05
– Modified the description of physics value in UHC_stC1~C5
– Added the monitoring variable of UHC_stCDfrst
– Modified the P1420 information in trouble shooting guide and fault code list
– Modified the description of physics value in CoSCR_stSub
sw ver: 02.14
date : Dec 04, 2023
– Change a condition of DPF service regeneration which is aligned with DL06/08 C4/S5 Excavator.
=> Environment Pressure: > 600hPa -> 400hPa
sw ver: 02.13
date : Sep 11, 2023
– Added variable PFltLd_mMaxSotM_C & Com_rPFltLdSot
sw ver : 02.12
date : Aug 28, 2023
– Added variable EpmCas_phiCaSOfsAvg_[0] & EpmCas_ctOfsErr
sw ver : 02.11
date : Jun 15, 2023
– Improved the IQA code of the injector to be downloaded when transter the ECU data
sw ver : 02.10
date : APR 25, 2023
– Changed to HD Hyundai infracore Template – Updated the “Test Info” of the engine test – Improves the problem of suddenly shutting down the program after 30 minutes when saving data while performing DPF forced regeneration with the scan too