Posted on

JCB excavator 140 205 C1024-13 Hydraulic Temperature Sensor Open Circuit

JCB excavator 140 205 C1024-13 Hydraulic Temperature Sensor Open Circuit (3)

This instruction show you guide on how to solve JCB excavator 140 205 DTC C1024-13 hydraulic temperature sensor open circuit.

 

Preparations:
2025 JCB ServiceMaster 4 v25.1.0

2017 JCB Parts Plus+ and Repair Service Manual

JCB Diagnostic Kit

 

 

Possible Cause:

1 Hydraulic oil temperature sensor not connected with the hydraulic oil temperature sensor.

2 Faulty Wire harness.

3 Faulty Hydraulic oil sensor.

 

Diagnosis:

1 Check wire harness connection with hydraulic oil temperature sensor. Refer below photograph.

2 Check the wire harness connector for terminal back out connecting to hydraulic oil temperature sensor.

JCB excavator 140 205 C1024-13 Hydraulic Temperature Sensor Open Circuit (1)

3 Check the MECU wire harness connector cavity 3 for 4303D circuit & cavity no 18 for circuit no 4003 for terminal back out.

JCB excavator 140 205 C1024-13 Hydraulic Temperature Sensor Open Circuit (2)

4 Check the open circuit resistance of hydraulic oil temperature sensor by help of multimeter. The open circuit resistance shall meet the below resistance vs temperature table.

JCB excavator 140 205 C1024-13 Hydraulic Temperature Sensor Open Circuit (3)

 

Corrective Action:

1 Replace the faulty wire harness.

2 Correct the terminal back out if any at temperature sensor or MECU END.

3 Replace the faulty temperature sensor.

4