Posted on

How to Solve Deutz EMR3 Charge Air Press 32 / 102 / BPSCD Error

This instruction show you guide on how to solve Deutz EMR3 Charge air press 32/102/BPSCD error.Charge air pressure sensor: the measured voltage of sensor by ECU is out of the target range; the calculated charge air pressure is implausible or the received value via CAN is defective.

 

Related Contents:

Deutz Serdia 4.0 Diagnostic Software

Deutz DECOM Interface Diagnostic Kit

 

Error codes

DEUTZ-Errorcode: 32

BlinkCode (short-long-short): 2 – 2 – 3

SPN: 102

 

Possible FMI:

3: Voltage to high or short circuit to +Ubatt

4: Voltage to low or short circuit to -Ubatt

2: data stream is defective

2: data stream is defective

 

Error Detection

Error lamp shows permanent light. Entry in error memory.

 

Possible reason for error

Cable break or short circuit, sensor defective, onnection cable  demaged

 

Take actions for error repair

Check cabling, if LDF6T sensor not working, check sensor and if

necessary replace it, check connection cable and if necessary repair or replace it

other error properties

 

System reaction: Warning, substitute value

Behaviour error lamp: permanent light

Self healing: yes

Signal Priority: 4

Measurement @ error time: default value