Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the following conditions:
• The signal from the secondary speed/timing sensor is lost and/or intermittent.
• The signal from the secondary speed/timing sensor was lost for at least 2 seconds while the signal

from the primary speed/timing sensor remained valid and the engine was running.
• Diagnostic code 0168-01 is not active.
• The engine has been running for more than 3 seconds.
• No 0041 diagnostic codes are active.

System Response:
If equipped, the diagnostic lamp will flash and the diagnostic code will be logged.

Possible Performance Effect:
If the signal from the secondary speed/timing sensor is lost and the engine is stopped, the engine will not restart. The performance will not be affected unless both speed signals are lost. The loss of the signals from both speed/timing sensors will cause the ECM to shut down the engine.

Troubleshooting:
This diagnostic code indicates that the signal from the secondary speed/timing sensor is incorrect.

Perform the following diagnostic procedure: “Engine Speed/Timing Sensor Circuit – Test”

Results:
• OK – STOP