Perkins 1106D EPG Engine CID 0172 FMI 04 Trouble Code Solution

Perkins 1106D EPG Engine CID 0172 FMI 04 Trouble Code Solution

Autoepccatalog.com show the instruction on how to solve Perkins 1106D Electric Power Generation CID 0172 FMI 04 trouble code.

Perkins 1106D EPG Engine CID 0172 FMI 04 Trouble Code Solution

Related Contents:

Perkins Communication Adapter 3 27610402

Perkins EST 2023A

Perkins SPI2 2018A Service and Parts Catalogs

 

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the following conditions:

• The signal voltage from the intake manifold air temperature sensor is less than 0.2 Volts DC formore than eight seconds.
• The ECM has been powered for at least two seconds.
• Diagnostic code 0168-01 is not active.

System Response:
If equipped, the diagnostic lamp will flash. The ECM will log the diagnostic code.
The ECM will use the default value of 70 °C (158°F) for the intake manifold air temperature. “Voltage Low” will be displayed next to the status for “Intake Manifold Air Temperature” on the electronic service tool.

Possible Performance Effect:
• Poor stability
• Poor cold running
• White smoke
• Black smoke
• Poor acceleration under load

Troubleshooting:
This fault can be caused by a sensor that is shorted to ground or a sensor that is internally shorted.
Perform the following diagnostic procedure: “Engine Temperature Sensor Open or Short Circuit – Test” Results:
• OK – STOP